- Produktkategorie
- Links
- Zuhause > Nachrichten > The use of magnetic pump and troubleshooting
Cautions
Fault and exclusion
Failure in the form |
Causes |
Remedy |
Pump no water |
Pump reversal Peng water pipe leak Impoundment too little of the pump chamber Voltage is too high, the slip coupling when the start Suction is too high |
Change the electrical wiring Community must leak Increase the storage capacity Adjusted voltage Reduce pump installation location |
Inadequate flow of |
Inhalation diameter too small Impeller duct obstruction Head is too high Speed ??is too low |
Swap the inlet Cleaning impeller To open a large outlet valve Restore summer rated speed |
Head is too low |
The amount of traffic Speed ??is too low |
Off a small outlet valve Restore the rated speed |
矂tone is too big |
Axis serious wear and tear Sleeve serious wear and tear Drive magnet cup and isolated sets of contacts |
Replace the pump shaft Replace the bushings Removal of pump head re-assembly |
Leakage |
0-type sealing rings of damage |
Replacing the 0-type sealing rings of |
keywords: Magnetic drive pump, magnetic pump, magnetic pump troubleshooting, chemical magnetic pump,
Sie sind der 54160 Besucher
Copyright © GuangDong ICP No. 10089450, Grandday Pump Co., Ltd All rights reserved.
Technischer Support: ShenZhen Immer Technology Development Co., Ltd
Immer Network 's Disclaimer: Die Legitimität des Enterprise Information übernimmt keine Garantie Verantwortung